Data set 01
1962 Cerberus
Published operating points and test conditions from this source.
Voltage Regulator
Characteristics
Stabilized voltage
102 to 107 V
1.5mA
Voltage regulation maximum
5 V
1-4mA
Current for full glow coverage
3 mA
Stabilized-voltage change over 20000 h maximum
5 V
1.5mA
Service life minimum
30000 h