Data set 01
1961 AEI Industrial Valves
Published operating points and test conditions from this source.
Rectifier
Other
Maximum RMS anode voltage
2000 V
Maximum working peak inverse voltage
5000 V
Maximum no-load peak inverse voltage
6000 V
Rectifier - Half Wave ·Rectifier
Special-quality indirectly heated high-vacuum half-wave rectifier for high-voltage, low-current supplies, providing approximately 5 kV inverse-voltage capability.
Special-quality indirectly heated high-vacuum half-wave rectifier.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum RMS anode voltage
2000 V
Maximum working peak inverse voltage
5000 V
Maximum no-load peak inverse voltage
6000 V
Data set 02
Published operating points and test conditions from this source.
Maximum RMS anode voltage
2 kV
Maximum no-load peak inverse voltage
6 kV
Maximum reservoir capacitance
1.1 uF
50Hz
Maximum shock
500 g
ShortDuration
Maximum acceleration
2.5 g
Continuous