Skip to main content

Rectifier - Half Wave ·Rectifier

RX21A

Eimac mercury-vapor half-wave rectifier designed for high peak inverse voltage with relatively low forward drop. Its single rectifying section is intended for high-voltage professional power supplies.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
2.5 V / 10 A

Description

EITEL-McCULLOU GH, INC. VAPOR The Eimac RX2IA is a half-wave mercury vapor rectifier incorporating features which enable it to withstand high peak inverse voltages and to conduct at relatively low applied voltages. The shielded ribbon filament, edgewise-wound, provides a large emmision reserve and long life. Voltage - - - - . - - R - - - - - 2.5 volts Current - - - - - - - . . . - - - 10 amperes Tube Voltage Drop (approx.) . . - - 15 volts

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
2.5 V
Nominal heater current
10 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
11000 V
Rectifier nominal output current
750 mA
Rectifier peak forward current
3 A
Rectifier forward voltage drop
15 V
Rectifier warm-up time
30 s

Promoted fields populated only where the published value maps directly to the schema; device-specific values retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Voltage - - - - . - - R

    2.5 V

    Voltage - - - - . - - R - - - - - 2.5 volts

  • Current

    10 A

    Current - - - - - - - . . . - - - 10 amperes

  • Tube Voltage Drop (approx.)

    15 V

    Tube Voltage Drop (approx.) . . - - 15 volts

  • PEAK INVERSE ANODE VOLTAGEz

    11000

    PEAK INVERSE ANODE VOLTAGEz - - - - - - - 11,000 MAX. YOLTS

  • PEAK ANODE CURRENT

    3 A

    PEAK ANODE CURRENT - - - - - - - - - - 3 MAX. AMPERES

  • AYERAGE ANODE CURRENT

    75 A

    AYERAGE ANODE CURRENT - - - - - - - - .75 MAX. AMPERES

  • SUPPLY FREQUENCY

    150

    SUPPLY FREQUENCY - - - - - - 150 MAX. C. P. S.

  • CONDENSED-MERCURY TEMPERATURE RANGE? [1]

    20

    CONDENSED-MERCURY TEMPERATURE RANGE? - - - - - - 20-60 °C

  • CONDENSED-MERCURY TEMPERATURE RANGE? [2]

    -60

    CONDENSED-MERCURY TEMPERATURE RANGE? - - - - - - 20-60 °C

  • Published value [1]

    2 V

    2Temperatures in excess of 60° C limit the peak-inverse rating to 5,000 volts with a corresponding reduction in

  • Published value [2]

    60 V

    2Temperatures in excess of 60° C limit the peak-inverse rating to 5,000 volts with a corresponding reduction in

  • Published value [3]

    5000 V

    2Temperatures in excess of 60° C limit the peak-inverse rating to 5,000 volts with a corresponding reduction in

  • conducting and tends to reduce the life of the filament. A temperature tifier and load, to prevent exceeding the maximum peak current of

    3

    conducting and tends to reduce the life of the filament. A temperature tifier and load, to prevent exceeding the maximum peak current of 3

  • ELECTRICAL current from exceeding

    3 A

    ELECTRICAL current from exceeding 3 amperes. This is for the usual case where the

  • value of [1]

    2.5 V

    value of 2.5 volts. Unavoidable variations in filament voltage must be In the single phase cricuits (1 and 3), if the current drawn by the

  • value of [2]

    1 V

    value of 2.5 volts. Unavoidable variations in filament voltage must be In the single phase cricuits (1 and 3), if the current drawn by the

  • value of [3]

    3 V

    value of 2.5 volts. Unavoidable variations in filament voltage must be In the single phase cricuits (1 and 3), if the current drawn by the

  • kept within the range of [1]

    2.4 V

    kept within the range of 2.4 to 2.6 volts. A filament voltage less than load is reduced or varies under operating conditions to values less

  • kept within the range of [2]

    2.6 V

    kept within the range of 2.4 to 2.6 volts. A filament voltage less than load is reduced or varies under operating conditions to values less

  • the minimum recommended value may cause a high tube voitage drop, than approximately

    70

    the minimum recommended value may cause a high tube voitage drop, than approximately 70% of the indicated maximum d-c load current, a

  • tions, a delay of approximately

    30 s

    tions, a delay of approximately 30 seconds will be required. The delay When ‘'condenser input'’ filter is used, the peak current will be rela-

  • tube. In radio transmitter applications the filament should be kept at the capacitor may be as high as

    1.4

    tube. In radio transmitter applications the filament should be kept at the capacitor may be as high as 1.4 times the nominal RMS voltage of

  • Published value [1]

    60

    .060 +.003 INPUT YOLTS* APPROX. D-C MAX. D-C

  • Published value [2]

    3

    .060 +.003 INPUT YOLTS* APPROX. D-C MAX. D-C

  • ' dition such that the peak inverse voltage is limited to

    5500 V

    ' dition such that the peak inverse voltage is limited to 5500 volts, the

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • PEAKINVERSEANODEVOLTAGE*

    11000 V

    PEAKINVERSEANODEVOLTAGE* -------------- 11,000MAXo VOLTS

  • PEAK ANODE CURRENT ----- I

    3 mA

    PEAK ANODE CURRENT ----- I ----------- 3 MAXo AMPERES

  • AVERAGE ANODE CURRENT

    75 mA

    AVERAGE ANODE CURRENT ----------------. 75 MAXo AMPERES

  • SUPPLYFREQUENCY

    150

    SUPPLYFREQUENCY ------------------ 150MAX. CIJS

  • CONDENSED-MERCURY TEMPERATURE RANGE** [1]

    20

    CONDENSED-MERCURY TEMPERATURE RANGE** ---------- 20-60° CENTIGRADE

  • CONDENSED-MERCURY TEMPERATURE RANGE** [2]

    -60

    CONDENSED-MERCURY TEMPERATURE RANGE** ---------- 20-60° CENTIGRADE

  • * Temperatures in excess of [1]

    60

    * Temperatures in excess of 60°C limit the peak-inverse rating to 5500 volts with a corresponding

  • * Temperatures in excess of [2]

    5500

    * Temperatures in excess of 60°C limit the peak-inverse rating to 5500 volts with a corresponding

  • Mounting: The RX2

    1 V

    Mounting: The RX21A must be mounted vertically, the recommended value raises the voltage at which

  • This tempera.ture should be malntalned at [1]

    40 V

    This tempera.ture should be malntalned at 40° ±5°C voltage as measured directly at the filament pins,

  • This tempera.ture should be malntalned at [2]

    5 V

    This tempera.ture should be malntalned at 40° ±5°C voltage as measured directly at the filament pins,

  • wlth±n the range ©f [1]

    24 V

    wlth±n the range ©f 2,4 to 2.8 volts, A fllanent voltage

  • wlth±n the range ©f [2]

    2.8 V

    wlth±n the range ©f 2,4 to 2.8 volts, A fllanent voltage

  • The filament of the RX2

    1

    The filament of the RX21A should be allowed to reach

  • imately

    30

    imately 30 seconds will be required. The delay time detrimental to tube life and make proper operation