Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Triode
Characteristics
Transconductance
55000 µS
Transconductance
55 mA/V mA/V
Other
Heater voltage
7,5 V V
Heater current
≈ 100 A A
Frequency
160 MHz MHz
Anode voltage (dc)
6,5 kV kV
Grid voltage (dc)
– 500 V V
Anode current (dc)
3,0 A A
Anode dissipation
10 kW kW
Grid dissipation
500 W W
Frequency
≤ 30 MHz MHz
Carrier power
11,9 kW kW
Anode voltage (dc)
5,0 kV kV
Grid bias (dc)
– 200 V V
Peak grid voltage (ac)
490 V V
Anode current (dc)
3,0 A A
Grid current (dc)
0,8 A A
Anode input power
15 kW A
Drive power
380 W W
Anode dissipation
3,1 kW kW
Grid dissipation
220 W W
Efficiency
79 %
Anode load resistance
825 Ω Ω
Transmitter Triode
2015 CL
Capacitance
Cathode/grid
≈ 59 pF pF
Cathode/anode
≈ 0,2 pF pF
Grid/anode
≈ 36 pF pF
Transmitter Triode
2015 CL