Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Triode
Characteristics
Amplification factor
15
Transconductance
20000 µS
Emission current
20 A A
Amplification factor
15
at UA = 1
6 kV, IA = 1 A kV
Transconductance
20 mA/V mA/V
Other
Heater voltage
10 V V
Heater current
≈ 70 A A
Frequency
70 MHz MHz
Anode voltage (dc)
8,0 kV kV
Grid voltage (dc)
– 1200 – 1200 V V
Cathode current (dc)
5,0 5,0 A A
Peak cathode current
20 A A
Anode dissipation
12 kW kW
Grid dissipation
100 60 W W
Frequency
≤ 30 ≤ 70 MHz MHz
Output power
12 kW 1) kW
Anode voltage (dc)
7,0 kV kV
Grid voltage (dc)
– 960 – 700 V V
Peak grid voltage (ac)
1260 950 V V
Anode current (dc)
2,8 2,3 A A
Grid current (dc)
275 250 mA mA
Anode input power
16 kW A
Drive power
335 210 W 1) W
Anode dissipation
6,0 4,0 kW kW
Grid dissipation
35 W W
Efficiency
78,5 75 %
Anode load resistance
1840 1500 Ω Ω
Triode
2011 V V
Frequency
30 MHz MHz
Anode voltage (dc)
6,5 kV kV
Grid voltage (dc)
– 1200 V V
Cathode current (dc)
5,0 A A
Peak cathode current
20 A A
Anode dissipation
12 kW kW
Grid dissipation
100 W W
Frequency
≤ 30 MHz MHz
Carrier power
6,0 kW 1) kW
Anode voltage (dc)
6,0 kV kV
Grid bias (dc), fixed
– 400 V V
Grid resistance
3,0 kΩ kΩ
Peak grid voltage (ac)
1260 V V
Anode current (dc)
1,25 A A
Grid current (dc)
210 mA mA
Anode input power
7,5 kW A
Drive power
260 W 1) W
Anode dissipation
1,5 kW 2) kW
Grid dissipation
40 W W
Efficiency
80 %
Anode load resistance
2,7 kΩ kΩ
Modulation factor
100 %
Modulation power
3,75 kW kW
Grid current (dc)
240 mA 3) mA
Drive power
295 W 1) 3) W
Grid current (dc)
200 mA 4) mA
Drive power
245 W 1) 4) W
tion the anode dissipation increases
1,5 times the power dissipation stated for the carrier value.
Triode
2011 V V
Anode voltage (dc)
11 kV kV
Grid voltage (dc)
– 1000 V V
Cathode current (dc)
5,0 A A
Peak cathode current
20 A A
Anode dissipation
12 kW kW
Grid dissipation
100 W W
Grid resistance
10 kΩ kΩ
Ugg
0 1950 0 1720 0 1500 V V
IG M
0 2 × 1,6 0 2 × 0,42 0 0 A A
PB A
2×3 2 × 26,7 2×3 2 × 11 2×3 2 × 15 kW A
RAA
– 4,15 – 10,1 – 6,1 kΩ kΩ
Triode
2011 V V
Anode voltage (dc)
11 kV kV
Grid voltage (dc)
– 1000 V V
Cathode current (dc)
5,0 A A
Peak cathode current
20 A A
Anode dissipation
12 kW kW
Grid dissipation
100 W W
Grid resistance
10 kΩ kΩ
Ugg
0 1470 0 1380 0 1220 V V
IG M
0 2 × 0,6 0 2 × 0,27 0 0 A A
PB A
2×2 2 × 11,2 2 × 1,6 2 × 7,2 2 × 1,2 2 × 8,8 kW A
RAA
– 6,12 – 9,8 – 5,5 kΩ kΩ
Triode
2011 V V
Anode voltage (dc)
11 kV kV
Grid voltage (dc)
– 1000 V V
Cathode current (dc)
5,0 A A
Peak cathode current
20 A A
Anode dissipation
12 kW kW
Grid dissipation
100 W W
Grid resistance
10 kΩ kΩ
Anode voltage (dc)
4,9 4,9 kV kV
Grid voltage (dc)
– 320 – 320 V V
between
2 tubes Ugg m 0 1550 V V
between
2 tubes Ukk m 0 910 V V
Cathode current (dc)
2 × 0,5 2 × 1,85 A A
Peak cathode current IK M (2 × 0,5)
2 × 9,8 A A
Anode input power
2 × 2,45 2 × 9,1 kW A
Capacitance
Cathode/grid
≈ 48 pF pF
Cathode/anode
≈ 1,3 pF 1) pF
Grid/anode
≈ 23 pF pF
Triode
2011 V V