Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Other
Us = 5 v
-
I, = 10 A bei U = Uy = Ugq = 400 V
-
rg2gt = 5 bei Uy = 2...6 kV, Ugz = 600...800 V,
-
f = 220 MHz
-
Ug2 = 800 v
-
Ug1 = -400 v
-
Qg2 = 100 w
-
Qg1 = 30 w
-
Ug2 = 600 v
-
Ugls = 240 v
-
Uag1 = 4,5 kV
-
Ug2gt = 800 v
-
Ukg1 = 400 v
-
Qg2 = 100 w
-
Qg1 = 30 w
-
f = 220 MHz
-
Uag1 = 4 KV
-
Ug2g1 = 750 v
-
Ukgis = 260 v 310 V
-
Ukgis = 310 V fir den Entlastungsfall gilt
-
f = 220 MHz
-
Ua = 2,5 KV
-
Ugt = -400 v
-
Ua = 2,5 KV
-
Ug2 = 1 KV
-
Ug1 = -180 v
-
Ugis = 300 v
-
Qa = 1,3 kw
-
2) fur Modulationsfrequenz nicht verblockt
-
Kthldaten fiir maximale Anodenverlustleistung...... oo Qa = 4 kW
-
Up=60k A/ 5
-
| ] Ug7=_+700 v
-
70 \ \ \ UgI=Parameter
-
U92 = 600 V
-
Ugz = 800 V
-
~180 Ugy= 600V
-
RS 1012 Ugy = 1 (Uy)ilg, = Perameter ,..2..,
-
Ugy= 600V
-
sHMENS U91 = f (Ua);'gz= Parameter
-
/A Ugp = 800V
-
+140 Ugy = f(Ua)
-
Ugy= 600 V
-
SIEMENS Ug1 = f (Ua) ;191 = Parameter
-
+140 Ugy= f(Ua)
-
Current
Ia=1A
-
S = 20 mA/V bei Ua =3 kV, Ug2a =600V, I5=1A
-
Ix = 2,5 A
-
Ixs = 8 A
-
Ik = 3 A
-
Iksp = 10 A
-
Ik = 2,5 A
-
Ikap = 9 A
-
Ig2 = 230 mA
-
Io = filg) [l 1] a7
-
a7—T Ig =f(Uy)
-
Igz = 1 (Up) ROHREN
-
+100 \\ B Io= 8A
-
RS 1012 Ugr = t Uy)ilgy = Parameter siEMEns
-
Capacitance
Ck-g1 = 34 pF
-
Ck-gZ = 4,5 pF
-
Ck-a = 0,11 pF
-
Cg1-g2 = 50 pF
-
Cgi-a = 0,18 pF
-
Cg2-a = 15 pF
-