Skip to main content

Voltage Tetrode ·Tetrode

RS1012L

Siemens directly heated transmitting tetrode. Available source material identifies the RS1012 family with professional RF-power service without supporting a more detailed description.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Tetrode

X-ray radiationInterelectrode capacitances
Transconductance
0.02 S

Ratings, characteristics, and operating tables audited semantically; repeated identical systems represented once where applicable.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Siemens

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Other

  • Us = 5 v

    -

  • I, = 10 A bei U = Uy = Ugq = 400 V

    -

  • rg2gt = 5 bei Uy = 2...6 kV, Ugz = 600...800 V,

    -

  • f = 220 MHz

    -

  • Ug2 = 800 v

    -

  • Ug1 = -400 v

    -

  • Qg2 = 100 w

    -

  • Qg1 = 30 w

    -

  • Ug2 = 600 v

    -

  • Ugls = 240 v

    -

  • Uag1 = 4,5 kV

    -

  • Ug2gt = 800 v

    -

  • Ukg1 = 400 v

    -

  • Qg2 = 100 w

    -

  • Qg1 = 30 w

    -

  • f = 220 MHz

    -

  • Uag1 = 4 KV

    -

  • Ug2g1 = 750 v

    -

  • Ukgis = 260 v 310 V

    -

  • Ukgis = 310 V fir den Entlastungsfall gilt

    -

  • f = 220 MHz

    -

  • Ua = 2,5 KV

    -

  • Ugt = -400 v

    -

  • Ua = 2,5 KV

    -

  • Ug2 = 1 KV

    -

  • Ug1 = -180 v

    -

  • Ugis = 300 v

    -

  • Qa = 1,3 kw

    -

  • 2) fur Modulationsfrequenz nicht verblockt

    -

  • Kthldaten fiir maximale Anodenverlustleistung...... oo Qa = 4 kW

    -

  • Up=60k A/ 5

    -

  • | ] Ug7=_+700 v

    -

  • 70 \ \ \ UgI=Parameter

    -

  • U92 = 600 V

    -

  • Ugz = 800 V

    -

  • ~180 Ugy= 600V

    -

  • RS 1012 Ugy = 1 (Uy)ilg, = Perameter ,..2..,

    -

  • Ugy= 600V

    -

  • sHMENS U91 = f (Ua);'gz= Parameter

    -

  • /A Ugp = 800V

    -

  • +140 Ugy = f(Ua)

    -

  • Ugy= 600 V

    -

  • SIEMENS Ug1 = f (Ua) ;191 = Parameter

    -

  • +140 Ugy= f(Ua)

    -

Current

  • Ia=1A

    -

  • S = 20 mA/V bei Ua =3 kV, Ug2a =600V, I5=1A

    -

  • Ix = 2,5 A

    -

  • Ixs = 8 A

    -

  • Ik = 3 A

    -

  • Iksp = 10 A

    -

  • Ik = 2,5 A

    -

  • Ikap = 9 A

    -

  • Ig2 = 230 mA

    -

  • Io = filg) [l 1] a7

    -

  • a7—T Ig =f(Uy)

    -

  • Igz = 1 (Up) ROHREN

    -

  • +100 \\ B Io= 8A

    -

  • RS 1012 Ugr = t Uy)ilgy = Parameter siEMEns

    -

Capacitance

  • Ck-g1 = 34 pF

    -

  • Ck-gZ = 4,5 pF

    -

  • Ck-a = 0,11 pF

    -

  • Cg1-g2 = 50 pF

    -

  • Cgi-a = 0,18 pF

    -

  • Cg2-a = 15 pF

    -