Data set 01
1962 Mullard Industrial Rectifiers
Published operating points and test conditions from this source.
Rectifier
Characteristic
Filling
Inert gas
Other
Cathode Peak Current
2 A
PIV5000V
Cathode Average Current
500 mA
PIV5000V
Maximum Supply Frequency
500 Hz
PIV5000V
Cathode Peak Current
1 A
PIV10000V
Cathode Average Current
250 mA
PIV10000V
Maximum Supply Frequency
150 Hz
PIV10000V
Cathode Surge Current
20 A
FaultProtection;MaximumDuration0.1s
Ambient Temperature
-55 to 75 C