Skip to main content

Rectifier - Half Wave ·Rectifier

RG43000

Directly heated mercury-vapor half-wave rectifier for high-voltage circuits. Its heavy filament and low arc voltage support operating regimes reaching several amperes.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
SJ4
Base pins
-
Nominal heater
5 V / 11.5 A

Description

Mercury-vapour half-wave rectifier for high-voltage rectifier circuits, with rating regimes extending to 25 kV peak inverse and 5 A average current. Promoted maxima are independent published maxima; source gives coupled rating regimes: 25 kV/20 A peak/5 A average and 10-15 kV/12 A peak/3 A average.

Socket description

Super-jumbo 4-contact bayonet

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
SJ4
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
11.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max cathode current
5 A
Rectifier peak inverse voltage
25000 V
Rectifier nominal output current
5 A
Rectifier peak forward current
20 A
Rectifier forward voltage drop
12 V
Rectifier warm-up time
60 s

Gas-discharge device.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Mullard Industrial Rectifiers

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filling

    Mercury vapour

Other

  • Cathode Surge Current

    200 A

    PIV2500V;FaultProtection;MaximumDuration0.1s

  • Cathode Surge Current

    120 A

    PIV10000to15000V;FaultProtection;MaximumDuration0.1s

  • Maximum Operating Frequency

    150 Hz

  • Condensed Mercury Temperature

    25 to 75 C

    PIV2500V

  • Condensed Mercury Temperature

    25 to 60 C

    PIV10000V

  • Condensed Mercury Temperature

    25 to 55 C

    PIV15000V

  • DC Output Voltage

    4800 V

    SinglePhaseFullWave;TwoValves;PIV15000V

  • DC Output Current

    6 A

    SinglePhaseFullWave;TwoValves;PIV15000V

  • DC Output Voltage

    790 V

    SinglePhaseFullWave;TwoValves;PIV2500V

  • DC Output Current

    10 A

    SinglePhaseFullWave;TwoValves;PIV2500V

Data set 02

1971 Mullard Gas Filled Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum average cathode current

    12 A

  • Maximum surge cathode current

    12 A

    Fault protection

  • Heater/filament voltage

    5 V

  • Heater/filament current

    11.5 A