Skip to main content

Rectifier - Half Wave ·Rectifier

RG41250

Directly heated mercury-vapor half-wave rectifier for substantial power conversion. Its massive filament and low arc voltage provide ampere-class output at high voltage.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
GOLIATH
Base pins
4
Nominal heater
4 V / 11 A

Description

Mercury-vapour half-wave rectifier for power rectification, rated up to 20 kV peak inverse and 1.25 A average cathode current. Ratings include 25 A surge current, 150 c/s maximum operating frequency, and mercury-temperature-dependent PIV limits.

Socket description

Goliath industrial rectifier base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
GOLIATH
Base pins
4
Nominal heater voltage
4 V
Nominal heater current
11 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max cathode current
1.25 A
Rectifier peak inverse voltage
20000 V
Rectifier nominal output current
1.25 A
Rectifier peak forward current
5 A
Rectifier forward voltage drop
12 V
Rectifier warm-up time
60 s

Gas-discharge device.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Mullard Industrial Rectifiers

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filling

    Mercury vapour

Other

  • Cathode Surge Current

    25 A

    FaultProtection;MaximumDuration0.1s

  • Maximum Operating Frequency

    150 Hz

  • Condensed Mercury Temperature at 20 kV PIV

    20 to 40 C

    PIV20000V

  • Condensed Mercury Temperature at 10 kV PIV

    20 to 55 C

    PIV10000V

  • Filament Voltage Maximum

    4.1 V

  • Filament Voltage Minimum

    3.9 V

  • DC Output Voltage

    6300 V

    SinglePhaseFullWave;TwoValves

  • DC Output Current

    2.5 A

    SinglePhaseFullWave;TwoValves

Data set 02

1971 Mullard Gas Filled Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum peak inverse anode voltage

    20 kV

  • Maximum average cathode current

    2 A

  • Maximum surge cathode current

    1.25 A

    Fault protection

  • Heater/filament voltage

    4 V

  • Heater/filament current

    11 A