Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Rectifier
Characteristics
Filament Voltage
5 V
Filament Current
6.75 A
Valve Voltage Drop
16 V
Approximate
Other
Peak Inverse Voltage
13000 V
<=150Hz
Peak Anode Current
5 A
Mean Anode Current
1.25 A
Ambient Temperature Minimum
10 degC
Ambient Temperature Maximum
40 degC
Condensed Mercury Temperature Minimum
25 degC
Condensed Mercury Temperature Maximum
65 degC
DC Output Voltage
4140 V
SinglePhaseFullWave; TwoValves
DC Output Current
2.5 A
SinglePhaseFullWave; TwoValves
RMS Input Voltage per Valve
4600 V
SinglePhaseFullWave
Minimum Choke Inductance
2.5 H
SinglePhaseFullWave; ChokeInputFilter
Maximum Filter Capacitance
6 uF
SinglePhaseFullWave