Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Rectifier
Other
Peak Inverse Voltage
10000 V
Peak Anode Current
1 A
Rectifier - Half Wave ·Rectifier
Mercury-vapor high-voltage half-wave rectifier, normalized from RG3-250. Its heavy filament and low arc voltage provide multiampere industrial output.
Mercury-vapor high-voltage rectifier normalized from printed type RG3-250, rated for 10 kV peak inverse voltage.
Edison screw base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Gas-discharge device.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Peak Inverse Voltage
10000 V
Peak Anode Current
1 A
Data set 02
Published operating points and test conditions from this source.
Average Cathode Current Used on Heating Curve
250 mA
HeatingCoolingCurve
Data set 03
Published operating points and test conditions from this source.
Maximum peak inverse anode voltage
10 kV
Maximum average cathode current
3 A
Maximum peak cathode current
1 A
Maximum surge cathode current
1 A
Fault protection
Heater/filament voltage
2.5 V
Heater/filament current
5 A