Skip to main content

Rectifier - Half Wave ·Rectifier

RG1240A

Mercury-vapor high-voltage half-wave rectifier, normalized from RG1-240A. Its heavy filament and low arc voltage provide ampere-class industrial power conversion.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B4
Base pins
4
Nominal heater
4 V / 2.7 A

Description

Mercury-vapor high-voltage rectifier normalized from printed type RG1-240A, rated for 6.5 kV peak inverse voltage.

Socket description

European 4-pin base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B4
Base pins
4
Nominal heater voltage
4 V
Nominal heater current
2.7 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max cathode current
250 mA
Rectifier peak inverse voltage
6500 V
Rectifier nominal output current
1.25 A
Rectifier peak forward current
1.25 A
Rectifier forward voltage drop
12 V

Gas-discharge device.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1951 Mullard Valve and Service Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak Inverse Voltage

    6500 V

  • Peak Anode Current

    1250 mA

Data set 02

1962 Mullard Industrial Rectifiers

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filling

    Mercury vapour

  • Nominal Ignition Voltage

    12 V

Other

  • Cathode Surge Current

    25 A

    FaultProtection;MaximumDuration0.1s

  • Maximum Operating Frequency

    150 Hz

  • Condensed Mercury Temperature

    25 to 65 C

  • Anode Supply Voltage per Valve RMS

    2220 V

    SinglePhaseFullWave

  • DC Output Voltage

    2000 V

    SinglePhaseFullWave;TwoValves

  • DC Output Current

    500 mA

    SinglePhaseFullWave;TwoValves

Data set 03

1971 Mullard Gas Filled Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum peak inverse anode voltage

    6.5 kV

  • Maximum average cathode current

    1.25 A

  • Maximum surge cathode current

    1.25 A

    Fault protection

  • Maximum operating frequency

    150 Hz

  • Heater/filament voltage

    4 V

  • Heater/filament current

    2.7 A