Skip to main content

Power - Beam (NOT sweep) (over 1000V 100W) ·BeamPower

RE20XL

Forced-air-cooled 20-kilowatt coaxial power-beam transmitting tetrode designed for oscillator and RF power-amplifier service to approximately 220 MHz.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12.6 V / 110 A

Description

Directly heated 20 kW coaxial power-beam transmitting tetrode for oscillator and RF power-amplifier service, rated to 220 MHz and cooled by forced air.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12.6 V
Nominal heater current
110 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Beam Power

X-ray radiationInterelectrode capacitances
Transconductance
0.06 S
Max plate voltage
8000 V
Max screen voltage
1250 V
Max plate dissipation
20000 W
Max screen dissipation
800 W
Max grid dissipation
500 W
Max cathode current
28 A

Semantically matched promoted fields only.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X Tesla

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Capacitance

  • Control-grid input capacitance

    90 pF

    Published interelectrode capacitance

  • Plate output capacitance

    35 pF

    Published interelectrode capacitance

Other

  • Maximum frequency

    220 MHz

    Published maximum/rated frequency

  • Heater data

    6-7 V; 180-220 A

    Published heater voltage/current range or limit

Data set 02

1966 Tesla Tubes

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Other

  • of

    6 to 7 V

  • If

    180 A to 220 A

  • 3KCHJIYATALU4OHHLIE AHHbIE Ua max.

    8 kV

  • Wa max.

    20 kW

  • Ug2 max.

    1250 V

  • Wg2 max.

    800 W

  • Wg1 max.

    500 W

  • Ik sp max.

    28 A

  • f max.

    220 Mc/s

  • OXJ

    1 A

Capacitance

  • Cgs

    90 pF

  • Ca

    35 pF

Characteristic

  • S

    60 mA/V

  • I.

    60 A