Data set 01
1959 Telefunken
Published operating points and test conditions from this source.
Tetrode
Characteristic
HeaterOrFilamentVoltage
4 V
HeaterOrFilamentCurrent
70 mA
Other
SpaceChargeGridVoltageMaximum
20 V
Voltage Pentode or Tetrode (under 100V) ·Tetrode
Directly heated space-charge-grid double-grid tube for very-low-anode-voltage detector and AF-amplifier service in portable battery receivers.
Directly heated space-charge-grid double-grid tube for very-low-anode-voltage detector and AF-amplifier service in portable battery receivers.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from the supplied Telefunken source where explicitly readable.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
4 V
HeaterOrFilamentCurrent
70 mA
SpaceChargeGridVoltageMaximum
20 V