Skip to main content

Power - Triode (over 1000V 100W) ·Triode

RD75YH

Power transmitting triode intended for RF amplification, oscillation, or related professional service. Manufacturer documentation emphasizes radio-frequency operation, useful power output, and transmitter or industrial applications.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
19 V / 130 A

Description

Directly heated thoriated-tungsten 75 kW transmitting triode for RF power amplifier or oscillator service up to 3 MHz; water-cooled anode with forced-air auxiliary cooling.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
19 V
Nominal heater current
130 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
4150 Ω
Amplification factor
48
Max plate voltage
20000 V
Max plate dissipation
75000 W
Max grid dissipation
3000 W

Published characteristic ranges are preserved in parameters when no single scalar is printed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X Tesla

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-to-cathode capacitance

    65 pF

    Published interelectrode capacitance

  • Plate-to-cathode capacitance

    7 pF

    Published interelectrode capacitance

  • Plate-to-grid capacitance

    45 pF

    Published interelectrode capacitance

Other

  • Maximum frequency

    3 MHz

    Published maximum/rated frequency

  • Heater data

    19 V; 125-135 A

    Published heater voltage/current range or limit

Characteristic

  • Amplification factor range

    44-52

    Published range

  • Plate resistance range

    3.8-4.5 kOhm

    Published range

Data set 02

1966 Tesla Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    19 V

  • Heater current

    125 A to 135 A

  • Maximum plate voltage

    20000 V

  • Maximum plate dissipation

    75000 W

  • Maximum control-grid dissipation

    3000 W

  • Maximum frequency

    3 MHz

  • Maximum plate voltage

    17000 V

    Oscillator; f < 3 MHz

Capacitance

  • Grid-cathode capacitance

    65 pF

  • Anode-cathode capacitance

    7 pF

  • Anode-grid capacitance

    45 pF

Characteristic

  • Amplification factor

    44 to 52

    Published range

  • Plate resistance

    3800 to 4500 ohm

    Published range