Skip to main content

Power - Triode ·Triode

RD24TA

German transmitting and control triode with published electrical ratings and operating data for professional RF service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

RD24TA: German transmitting/control triode with published electrical ratings and operating data. The German-language datasheet was translated and interpreted by technical meaning, with ratings and characteristics preserved.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
400 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.006 S
Max cathode current
30 mA

Published ratings and characteristics promoted; additional useful values retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

194X Wehrmacht Rohren

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Heater current

    400 mA

  • Transconductance

    6000 uS

Other

  • Maximum cathode/anode current

    30 mA