Skip to main content

Power - Triode (over 1000V 100W) ·Triode

RD20XF

Forced-air-cooled directly heated Tesla transmitting triode for low- and high-frequency power amplification and oscillator service. Approximately 20 kW plate dissipation and 15 kV capability support major professional RF systems.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Forced-air-cooled directly heated transmitting triode with 20 kW anode dissipation for low- or high-frequency power amplification and oscillation up to 30 MHz.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
15000 V
Max plate dissipation
20000 W

Promoted fields populated from published maximum-ratings/characteristic tables where OCR semantics were unambiguous.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X Tesla

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater Voltage

    19 to 21 V

    Published range

  • Heater Current

    220 A to 240 A

    Published range

  • Maximum Plate Voltage

    15000 V

    Highest published maximum rating

  • Maximum Plate Dissipation

    20000 W

  • Maximum Frequency

    30 MHz

Data set 02

1966 Tesla Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    19 to 21 V

  • Heater current

    220 A to 240 A

  • Cooling water flow

    500 L/min

    Cooling