Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Tetrode
Other
Maximum operating frequency
500 MHz
RF operating frequency
500 MHz
ClassC
RF plate voltage
180 V
ClassC
RF screen voltage
180 V
ClassC
RF control-grid voltage
-20 V
ClassC
RF plate current per section
27.5 mA
ClassC
RF output power
5.8 W
ClassC
Plate dissipation maximum per section
3 W
Screen dissipation maximum per section
1.5 W
Heater-cathode voltage maximum
100 V
Capacitance
Plate-grid capacitance per section
0.16 pF
Push-pull input capacitance
3.8 pF
PushPull
Push-pull output capacitance
0.95 pF
PushPull
Grid-to-all capacitance per section
6.4 pF
Plate-to-all capacitance per section
1.6 pF
Characteristics
Transconductance
10.5 mA/V
Application
Application
RF power amplifier / oscillator / frequency multiplier