Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Tetrode
Characteristic
Cathode: oxyde Vf
12.6 V
| Cathode: oxyde Vf = 6.3 12.6 V 1 )
Katode : Oxyd
300 mA
| Katode : Oxyd 0.6 0.3 A
should not exceed
7 V
Cooling | should not exceed 7 V or 14 V and the accumulator may be
should not exceed
14 V
Cooling | should not exceed 7 V or 14 V and the accumulator may be
actuel ne surpassera pas
7 V
Cooling | actuel ne surpassera pas 7 V ou 14 V et 1'accumulateur
actuel ne surpassera pas
14 V
Cooling | actuel ne surpassera pas 7 V ou 14 V et 1'accumulateur
maniere que Vf
5.7 V
Cooling | maniere que Vf = 5.7 V ou 11.4 V
maniere que Vf
11.4 V
Cooling | maniere que Vf = 5.7 V ou 11.4 V
Eine voribergehende Abweichung von Vf von
1 s
Cooling | Eine voribergehende Abweichung von Vf von 10 % 1st zu-
Capacitance
Plate capacitance
1.6 pF
Capacitances | Ca = 1.6 pF Co = 0.95 pF
Plate capacitance
0.95 pF
Capacitances | Ca = 1.6 pF Co = 0.95 pF
Control-grid capacitance
6.4 pF
Capacitances | Cg1 = 6.4 pF C1 = 3.8 pF
Control-grid capacitance
3.8 pF
Capacitances | Cg1 = 6.4 pF C1 = 3.8 pF
Grid-to-plate capacitance
0.16 pF
Capacitances | Cag1 = 0.16 pF
Other
Typical characteristics per system Va
150 V
Typical characteristics | Typical characteristics per system Va = 150 V
Kenndaten pro System Vg
150 V
Typical characteristics | Kenndaten pro System Vg2 = 150 V
Plate current
25 mA
Typical characteristics | Ia = 25 mA
Transconductance
10.5 mA/V
Typical characteristics | S = 10.5 mA/V
f = max
500 ma
Maximum ratings | f = max. 500 max. 500 Mc/s
f = max
500 MHz
Maximum ratings | f = max. 500 max. 500 Mc/s
Plate voltage
250 ma
Maximum ratings | Va = max. 250 max. 250 V
Plate voltage
250 V
Maximum ratings | Va = max. 250 max. 250 V
Wia = max
6 ma
Maximum ratings | Wia = max. 2x6 max. 2x7 W
Wia = max
7 W
Maximum ratings | Wia = max. 2x6 max. 2x7 W
Wa = max
3 ma
Maximum ratings | Wa = max. 2x3 max. 2x3.75 W
Wa = max
3.75 W
Maximum ratings | Wa = max. 2x3 max. 2x3.75 W
Plate current
45 ma
Maximum ratings | Ia = max. 2x45 max. 2x50 mA
Plate current
50 mA
Maximum ratings | Ia = max. 2x45 max. 2x50 mA
Screen-grid voltage
200 ma
Maximum ratings | Vg2 = max. 200 max. 200 V
Screen-grid voltage
200 V
Maximum ratings | Vg2 = max. 200 max. 200 V
Wg
1.5 ma
Maximum ratings | Wg2 = max. 2x1.5 max. 2x1.75 w
Wg
1.75 w
Maximum ratings | Wg2 = max. 2x1.5 max. 2x1.75 w
Vg t = max
100 ma
Maximum ratings | -Vg t = max. 100 max. 100 V
Vg t = max
100 V
Maximum ratings | -Vg t = max. 100 max. 100 V
Igi = max
3 ma
Maximum ratings | Igi = max. 2x3 max. 2x4 mA
Igi = max
4 mA
Maximum ratings | Igi = max. 2x3 max. 2x4 mA
Vkf = max
100 ma
Maximum ratings | Vkf = max. 100 max. 100 V
Vkf = max
100 V
Maximum ratings | Vkf = max. 100 max. 100 V
f
500 MHz
Maximum ratings | f = 500 500 Mc/s
Plate voltage
200 V
Maximum ratings | Va = 180 200V
Screen-grid voltage
200 V
Maximum ratings | Vg2 = 180 200 V
Control-grid voltage
20 V
Maximum ratings | Vg1 = -20 20V
Vg
50 V
Maximum ratings | Vg1g1'p = 50 50 V
Plate current
31 mA
Maximum ratings | Ia = 2x27.5 2x31 mA
Screen-grid current
14 mA
Maximum ratings | Ig2 = 12.5 14 mA
Igi
0.75 mA
Maximum ratings | Igi = 2x0.75 2x0.75 mA
Wia
6.2 W
Maximum ratings | Wia = 2x5 2x6.2 W
Wa
2.6 W
Maximum ratings | Wa = 2x2.1 2x2.6 W
Wg
2.8 W
Maximum ratings | Wg2 = 2.25 2.8 W
Wig
1.2 W
Maximum ratings | Wig1 2) = 1.2 1.2W