Data set 01
1963 Ferranti
Published operating points and test conditions from this source.
MicrowaveTRSwitch
Characteristic
Loaded Q
- to 150
Low level maximum
Insertion loss
- to 2 dB
Low level maximum
Nominal peak power
20 kW
High power
Nominal mean power
8 W
High power
Maximum spike leakage energy
0.045 erg/pulse
High power
Maximum flat leakage power
25 mW
High power
Maximum recovery time to 3 dB
2 us
High power
Maximum recovery time to 1 dB
4 us
High power
Frequency
Tuning wavelength
8.4 to 8.8 mm
Q-band tuning range
Other
Primer supply voltage
-2000 V
Negative D.C.
Primer current
50 to 75 uA
Primer electrode