Skip to main content

Specialized - Switching Tube ·MicrowaveTRSwitch

QF50

Tunable Q-band TR gas-discharge cell with primer electrodes for microwave receiver protection. Ionization rapidly isolates sensitive circuitry during transmission.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Ferranti QF50 is a tuneable Q-band T.R. gas-discharge cell using primer electrodes. It is characterized for roughly 20 kW nominal peak power, low leakage and microsecond recovery for microwave receiver protection.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Microwave T.R. gas-discharge cell; device-specific primer, breakdown, leakage, recovery, frequency and power data are retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Ferranti

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Characteristic

  • Loaded Q

    - to 150

    Low level maximum

  • Insertion loss

    - to 2 dB

    Low level maximum

  • Nominal peak power

    20 kW

    High power

  • Nominal mean power

    8 W

    High power

  • Maximum spike leakage energy

    0.045 erg/pulse

    High power

  • Maximum flat leakage power

    25 mW

    High power

  • Maximum recovery time to 3 dB

    2 us

    High power

  • Maximum recovery time to 1 dB

    4 us

    High power

Frequency

  • Tuning wavelength

    8.4 to 8.8 mm

    Q-band tuning range

Other

  • Primer supply voltage

    -2000 V

    Negative D.C.

  • Primer current

    50 to 75 uA

    Primer electrode