Skip to main content

Specialized - Switching Tube ·MicrowaveTRSwitch

QF41A

Tunable X-band integral-cavity TR gas-discharge cell with primer electrode and preset tuning, designed for radar receiver protection.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Ferranti QF41A is an X-band tuneable integral-cavity T.R. gas-discharge cell for branched duplexers in WG16 waveguide. A primer electrode supports rapid firing, and the sheet specifies 50 kW peak power plus leakage and recovery limits.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Microwave T.R. gas-discharge cell; device-specific primer, breakdown, leakage, recovery, frequency and power data are retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Ferranti

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Other

  • Maximum transmitter power

    50 kW

    Peak

  • Primer supply voltage

    -1500 to -700 V

    Negative D.C. supply limits

  • Primer current

    100 to 200 uA

    Primer electrode

Characteristic

  • Preset tuning span

    75 Mc/s

    Approximately ±75 Mc/s

  • Loaded Q

    125 to 160

    Low power

  • VSWR at resonance

    - to 1.4

    Low power; average and limit

  • Insertion loss

    - to 1.2 dB

    Low power; average and limit

  • Flat leakage power

    - to 30 mW

    40 kW high-power test

  • Spike leakage energy

    - to 0.1 erg/pulse

    40 kW high-power test

  • Breakdown power

    - to 250 mW

    High power

  • Recovery time to -6 dB

    - to 4 us

    High power

  • Primer operating voltage

    250 to 450 V

    Approximate operating range from table

Frequency

  • Operating frequency

    9005 to 9155 Mc/s

    QF41A suffix range