Skip to main content

Specialized - Switching Tube ·MicrowaveTRSwitch

QF40

Integral-cavity high-Q 3-cm-band TR cell for radar duplexer and crystal-protection service. Gas discharge protects sensitive receiver components during transmitter pulses.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Integral-cavity high-Q 3-cm-band T.R. cell for radar duplexer and crystal protection service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Published Ferranti ratings and characteristics promoted where applicable; additional electrical, pulse, regulator, microwave, and operating data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Ferranti

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Application

  • Application

    3-cm-band radar T.R. duplexer protection cell

Other

  • Transmitter peak power maximum

    50 kW

    Pulse

  • VSWR maximum

    2

  • Insertion loss maximum

    1.5 dB

  • Leakage spike energy maximum

    0.04 erg/pulse

    Pulse

  • Leakage flat power maximum

    15 mW

    Pulse

  • Breakdown power minimum

    100 mW

  • Recovery time to 6 dB loss maximum

    15 us

  • Keep-alive breakdown voltage maximum

    1000 V

  • Typical VSWR

    1.4

  • Typical insertion loss

    1.2 dB

  • Typical leakage spike energy

    0.02 erg/pulse

    Pulse

  • Typical leakage flat power

    10 mW

    Pulse

  • Typical breakdown power

    40 mW

  • Typical recovery time to 6 dB loss

    2.5 us

  • Typical keep-alive breakdown voltage

    700 V

  • Typical keep-alive potential drop

    350 V

  • Keep-alive supply voltage

    -1000 V

  • Keep-alive current minimum

    100 uA

  • Keep-alive current maximum

    150 uA

  • Keep-alive series resistance minimum

    1 Mohm

Characteristics

  • Nominal tuning frequency

    9500 MHz

  • Tuning range tolerance

    5 %