Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Rectifier
Other
RMS input voltage maximum
250 V
CapacitorInputFilter
Surge anode current maximum
7.5 A
Pulse
Reservoir capacitance maximum
100 uF
CapacitorInputFilter
Typical rectifier operating point
200 V RMS input; 325 mA output; 182 V DC; 23 ohm minimum series resistance
CapacitorInputFilter
Typical rectifier operating point
220 V RMS input; 296 mA output; 212 V DC; 27 ohm minimum series resistance
CapacitorInputFilter
Typical rectifier operating point
240 V RMS input; 238 mA output; 248 V DC; 31 ohm minimum series resistance
CapacitorInputFilter
Typical rectifier operating point
250 V RMS input; 210 mA output; 264 V DC; 33 ohm minimum series resistance
CapacitorInputFilter