Data set 01
1967 Mullard Receiving and Amplifying Valves
Published operating points and test conditions from this source.
Pentode
Characteristic
Plate voltage
170 V
Screen-grid voltage
170 V
Grid voltage
-1.3 V
Plate current
30 mA
Screen-grid current
6.5 mA
Transconductance
40000 uS
Capacitance
Input capacitance
20 pF
Output capacitance
4 pF
Plate-grid capacitance
0.075 pF
Other
Plate supply voltage
400 V
VideoOutput
Plate voltage at zero cathode current
550 V
VideoOutput
Screen-grid voltage at zero cathode current
550 V
VideoOutput
Output voltage peak-to-peak
140 V
VideoOutput
Maximum output current
7 mA