Data set 01
1963 Philips Electron Tubes Handbook V3
Published operating points and test conditions from this source.
IgnitronPowerSwitch
Capacitance
Capacites Cag
7 pF
Capacitances | Capacites Cag = 7 pF
Grid-cathode capacitance
10 pF
Capacitances | Cgk = 10 pF
Other
Arc voltage drop
12 V
Typical characteristics | Varc = 12 V
Ionization time
10 µsec
Typical characteristics | Tion = 10 µsec
Deionization time
500 µsec
Typical characteristics | Tdion = 500 µsec
Peak anode voltage
1500 V
Limiting values | Vap =.max. 1000 1500 V
Grid voltage
300 V
Limiting values | -Vg = max. 500 300 V
Grid voltage
10 V
Limiting values | -Vg = max. AO 10 V2 )
Cathode current
15 s
Limiting values | Ik(Tav = max.15 sec) = max. 3.6 3.2 A
Cathode current
3.2 A
Limiting values | Ik(Tav = max.15 sec) = max. 3.6 3.2 A
Grid current
250 mA
Limiting values | Ig = max. 0.25 0.25 A
Surge current
200 A
Limiting values | Isurge(Tav max.0.lsec)= max. 200 200 A3 )
Peak anode voltage
1000 V
Limiting values | Vap = max. 1500 1000 V
Grid voltage
300 V
Limiting values | -Vg = max. 300 300 V
Grid voltage
10 V
Limiting values | -Vg = max. 10 10 V2)
Cathode current
15 s
Limiting values | Ik (Tav = max. 15 sec) = max. 0.5 1.25 3.2 3.6 A
Cathode current
3.6 A
Limiting values | Ik (Tav = max. 15 sec) = max. 0.5 1.25 3.2 3.6 A
Peak cathode current
40 A
Limiting values | Ikp = max. 40 A
Grid current
8 A
Limiting values | Ig = max. 28 14 8 Aeff6)
Surge current
200 A
Limiting values | Isurge(Tav = max.0.lsec)= max. 200 200 A3)