Data set 01
1963 Philips Electron Tubes Handbook V3
Published operating points and test conditions from this source.
IgnitronPowerSwitch
Capacitance
Capacites Cag
3 pF
Capacitances | Capacites Cag = 3 pF
Kapazitaten Cgk
14 pF
Capacitances | Kapazitaten Cgk = 14 pF
Other
Kenndaten Varc
10 V
Typical characteristics | Kenndaten Varc = 10 V
Ionization time
10 µsec
Typical characteristics | Tion = 10 µsec
Deionization time
1000 µsec
Typical characteristics | Tdion = 1000 µsec
Peak anode voltage
900 V
Limiting values | Vap = max. 900 V
Grid voltage
300 V
Limiting values | -Vg = max. 300 V3)
Grid voltage
10 V
Limiting values | -Vg = max. 10 V4)
Peak cathode current
30 A
Limiting values | Ikp = max. 30 A
Cathode current
5 s
Limiting values | Ik (Tav = 5 sec.) = max. 2.5 A
Cathode current
2.5 A
Limiting values | Ik (Tav = 5 sec.) = max. 2.5 A
lsurge (max
0.1 s
Limiting values | lsurge (max. 0.1 sec.) = max. 300 A5)
lsurge (max
300 A
Limiting values | lsurge (max. 0.1 sec.) = max. 300 A5)
Igp = max
500 mA
Limiting values | Igp = max. 0.5 A