Data set 01
1963 Philips Electron Tubes Handbook V3
Published operating points and test conditions from this source.
Thyratron
Characteristic
Heizung : direkt If
5 A
| Heizung : direkt If = 5.0 A
Capacitance
Capacitances Cag
3.3 pF
Capacitances | Capacitances Cag = 3.3 pF
Kapazitaten Cgk
5 pF
Capacitances | Kapazitaten Cgk = 5.0 pF
Other
Varc
12 V
Typical characteristics | Varc 12 V
Peak anode voltage
2500 V
Limiting values | Vap = ma.. 2500 V
Peak inverse anode voltage
5000 V
Limiting values | Va invp = max. 5000 V
Grid voltage
10 V
Limiting values | _Vg = max. 10 V1 )
Iap (f <
25 Hz
Limiting values | Iap (f < 25 c/s) max. 1A
Iap (f <
1 A
Limiting values | Iap (f < 25 c/s) max. 1A
Iap (f ?
2 A
Limiting values | Iap (f ? 25 c/a) = max. 2A
Anode current
15 s
Limiting values | Ia (Tav = max. 15 s)= max. 0.5 A
Anode current
500 mA
Limiting values | Ia (Tav = max. 15 s)= max. 0.5 A
Grid current
15 s
Limiting values | Ig (Tav = max. 15 s)= max. 0.05 A
Grid current
50 mA
Limiting values | Ig (Tav = max. 15 s)= max. 0.05 A
trig
-80 degC
Limiting values | trig = 35-80 °C
Surge current
0.1 s
Limiting values | Isurge (T=max.0.1 s) = max. 40 A
Surge current
40 A
Limiting values | Isurge (T=max.0.1 s) = max. 40 A
L (VA VA VA VAYAY
4 V
Limiting values | L (VA VA VA VAYAY4 V.