Skip to main content

Specialized - Thyratron ·Thyratron

PL2D21

Gas-filled tetrode thyratron for relay service, electronic timers, stabilized rectifiers, and grid-controlled rectifiers.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 600 mA

Description

Gas-filled tetrode thyratron for relay service, electronic timers, stabilized and grid-controlled rectifiers.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
100 mA

Promoted only where the locked schema has a direct semantic match; additional CRT, regulator, thyratron, pulse, capacitance, and operating values are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Arc voltage drop

    8 V

    Thyratron

  • Ionization time

    0.5 µs

    Thyratron

  • Deionization time

    35 µs

    Thyratron

  • Critical grid current

    0.5 µA

    Va460V;Ia0.1A

Other

  • Peak forward anode voltage maximum

    650 V

    Thyratron

  • Peak inverse anode voltage maximum

    1300 V

    Thyratron

  • Peak cathode/anode current maximum

    500 mA

    Thyratron

  • Average cathode/anode current maximum

    100 mA

    Thyratron

  • Relay-service anode voltage

    400 V RMS

    RelayService

Construction

  • Gas/fill

    Gas filled

    Thyratron

Data set 02

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Warm-up time

    20 s

Other

  • Heater voltage tolerance

    10 %