Data set 01
1963 Philips Electron Tubes Handbook V3
Published operating points and test conditions from this source.
Thyratron
Characteristic
Arc voltage drop
12 V
Thyratron
Ionization time
10 µs
Thyratron
Deionization time
1000 µs
Thyratron
Other
Peak forward anode voltage maximum
240 V
Thyratron
Peak inverse anode voltage maximum
500 V
Thyratron
Peak cathode/anode current maximum
90 A
Thyratron
Average cathode/anode current maximum
15 A
Thyratron
Surge current maximum
750 A
0.1Second
Construction
Gas/fill
Mercury vapor and gas
Thyratron