Skip to main content

Specialized - Thyratron ·Thyratron

PL10

Directly heated gas-filled triode with highly insulated external grid for pulse and relay circuits. Grid triggering provides controlled discharge switching.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
1.85 V / 3.4 A

Description

Directly heated gas-filled triode with a highly insulated external grid for pulse and relay circuits.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
1.85 V
Nominal heater current
3.4 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
100 mA

Promoted only where the locked schema has a direct semantic match; additional CRT, regulator, thyratron, pulse, capacitance, and operating values are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Arc voltage drop minimum

    20 V

    PulseRelay

  • Arc voltage drop maximum

    35 V

    PulseRelay

Other

  • Peak forward voltage maximum

    400 V

    PulseRelay

  • Peak inverse voltage maximum

    400 V

    PulseRelay

  • Average anode current maximum

    100 mA

    PulseRelay

  • Peak anode current maximum

    4 A

    PulseRelay

  • Positive grid peak voltage maximum

    1800 V

    PulseRelay

  • Negative grid peak voltage maximum

    1800 V

    PulseRelay

  • Grid resistance maximum

    10 MΩ

    PulseRelay

  • Ambient temperature range

    -75 to +90 °C

    PulseRelay

Data set 02

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Arc voltage minimum

    20 V

    Ia=0.1-4A

  • Arc voltage maximum

    35 V

    Ia=0.1-4A