Data set 01
1967 Mullard Receiving and Amplifying Valves
Published operating points and test conditions from this source.
Triode
Characteristic
Plate voltage
100 V
TriodeSection
Plate current
9 mA
TriodeSection
Grid voltage
-1 V
TriodeSection
Transconductance
8800 uS
TriodeSection
Amplification factor
50
TriodeSection
Capacitance
Input capacitance
3.3 pF
TriodeSection
Output capacitance
1.7 pF
TriodeSection
Plate-grid capacitance
1.8 pF
TriodeSection
Hexode
Characteristic
Plate voltage
14 V
HeptodeSection
Grids 2+4 voltage
14 V
HeptodeSection
Plate current
1.5 mA
HeptodeSection
Grids 2+4 current
1.3 mA
HeptodeSection
Grid 3 current
1 uA
HeptodeSection
Capacitance
Input capacitance
4.4 pF
HeptodeSection
Output capacitance
5.4 pF
HeptodeSection
Plate-grid1 capacitance
0.1 pF
HeptodeSection