Data set 01
1953 RFT Rundfunk Technik
Published operating points and test conditions from this source.
Pentode
Other
HeaterVoltageNominal
12.6 V
Nominal
HeaterCurrentNominal
750 mA
Nominal
Maximum Plate Voltage
1000 V
Maximum Screen Voltage
300 V
Maximum Plate Dissipation
40 W
Maximum Screen Dissipation
5 W
MaximumGridDissipation
1 W
Maximum Cathode Current
230 mA
Characteristic
Transconductance
3500 µS
Typical