Data set 01
1971 RCA HB3 Binder 2 of 7
Published operating points and test conditions from this source.
Voltage Regulator
Other
Average starting current
- to 100 mA
Starting period <=10 s
DC cathode current maximum
- to 40 mA
Steady-state
DC cathode current minimum
5 to - mA
Steady-state
Ambient temperature minimum
-55 to - °C
Ambient temperature maximum
- to 90 °C
Shunt capacitor maximum
- to 0.1 µF
Characteristics
DC anode starting voltage maximum
- to 210 V
Total darkness
DC anode starting voltage average
115 V
Normal ambient light 5 to 50 footcandles
DC anode starting voltage maximum
- to 127 V
Normal ambient light 5 to 50 footcandles
Anode voltage drop average
105 V
DC cathode current 5 mA
Anode voltage drop average
105 to 111 V
DC cathode current 30 mA
Anode voltage drop average
105 to 112 V
DC cathode current 40 mA
Regulation average
1 V
DC cathode current 5 to 30 mA
Regulation maximum
- to 2 V
DC cathode current 5 to 30 mA
Regulation average
2 V
DC cathode current 5 to 40 mA
Regulation maximum
- to 4 V
DC cathode current 5 to 40 mA
Tube noise maximum
- to 15 mV rms
DC cathode current 40 mA
DC leakage current maximum
- to 10 µA
DC anode supply 50 V; anode resistor 3000 ohms