Skip to main content

Nixie ·Nixie

NL902

Long-life neon-filled cold-cathode numerical readout tube displaying digits 0–9 with decimal-point capability. National Electronics documentation specifies 170 V maximum ionization and minimum supply voltage with operating-current limits for the cathodes.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
RTS14
Base pins
-
Nominal heater
-

Description

NL902 is a long-life neon-filled cold-cathode display/readout tube displaying numerals 0–9 with decimal-point capability. The supplied sheet specifies a 170 V maximum ionization voltage, 170 V minimum supply, and published cathode-current limits.

Socket description

National Electronics 13-contact Nixie/readout tube socket family

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
RTS14
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
3.5 mA

Cold-cathode glow display section; peak cathode-current limit promoted.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1968 Nixie National Electronics

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Ionization Voltage Maximum

    170 V

    Published technical information

  • Peak Cathode Current Maximum

    3.5 mA

    Published technical information

  • Average Cathode Current Maximum

    3 mA

    Published technical information

  • Ambient Temperature Minimum

    -20 degC

    Normal life range

  • Ambient Temperature Maximum

    55 degC

    Normal life range

  • Decimal Point Current Maximum

    0.5 mA

    Published technical information

  • Recommended Supply Voltage

    170 V

    Published technical information

  • Recommended Supply Voltage

    250 V

    Published technical information

  • Recommended Supply Voltage

    300 V

    Published technical information

Characteristic

  • Supply Voltage Minimum

    170 V

    Published technical information

  • Average Cathode Current Minimum

    1.5 mA

    Published technical information

  • Prebias Voltage Minimum

    60 V

    Off cathodes

  • Prebias Voltage Maximum

    120 V

    Off cathodes

  • Dynamic Life

    200000 h

    Published dynamic life

  • Decimal Point Current Minimum

    0.1 mA

    Published technical information