Data set 01
1956 National Electronics Industrial Tubes
Published operating points and test conditions from this source.
Triode
Other
18 Amperes do
160 Ampere peak A
Source technical-information table; wording preserved from datasheet.
do Amperes output (Maximum)
18 | 16 A
Source technical-information table; wording preserved from datasheet.
Instantaneous amperes output (Maximum)
100 | 160 A
Source technical-information table; wording preserved from datasheet.
Maximum time of averaging anode current (seconds)
4.5 A
Source technical-information table; wording preserved from datasheet.
Maximum peak inverse volts
1250 V
Source technical-information table; wording preserved from datasheet.
Maximum peak forward volts
1000 V
Source technical-information table; wording preserved from datasheet.
Max. commutation factor (V/usec. x A/usec.) at max. initial inverse voltage of 330 volts
0.66 V
Source technical-information table; wording preserved from datasheet.
Filament volts
2.5 V
Source technical-information table; wording preserved from datasheet.
Filament amperes
31 ± 3 A
Source technical-information table; wording preserved from datasheet.
Filament heating time (seconds)
60 s
Source technical-information table; wording preserved from datasheet.
Maximum negative grid voltage before conduction (volts)
100 V
Source technical-information table; wording preserved from datasheet.
Maximum negative grid voltage during conduction (volts)
10 V
Source technical-information table; wording preserved from datasheet.
Maximum critical grid current (microamps)
10 A
Source technical-information table; wording preserved from datasheet.
Maximum ac short circuit current (amperes)
1000 A
Source technical-information table; wording preserved from datasheet.
Ambient temperature lim its (°C)
—55 to +75 C
Source technical-information table; wording preserved from datasheet.
Net weight (ounces)
32 oz
Source technical-information table; wording preserved from datasheet.
Approx. shipping weight (lbs.)
31A lb
Source technical-information table; wording preserved from datasheet.
ANODE
w | 4-
Source technical-information table; wording preserved from datasheet.
PERCET DUTY
2 TUBES CONNECTED
Source technical-information table; wording preserved from datasheet.
Characteristic
Typical arc drop at 50 amperes peak (volts)
12 V
Source technical-information table; wording preserved from datasheet.
Ionization time (approx., microseconds)
10 us
Source technical-information table; wording preserved from datasheet.
Deionization time (approx. microseconds)
1000 us
Source technical-information table; wording preserved from datasheet.
Anode to grid capacitance (uuf) (approx.)
8 pF
Source technical-information table; wording preserved from datasheet.