Skip to main content

Power - Triode (over 1000V 100W) ·Triode

NL1096

Ceramic-metal power triode designed for Class C industrial RF oscillators, particularly dielectric-heating equipment. With about 10 kV plate capability and 10 kW dissipation, it provides rugged multi-kilowatt high-frequency power.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
7.5 V / 100 A

Description

High-performance ceramic/metal power triode for industrial Class C high-power oscillator service in dielectric-heating equipment.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
7.5 V
Nominal heater current
100 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
20
Max plate voltage
10000 V
Max plate dissipation
10000 W
Max grid dissipation
250 W
Max cathode current
4 A

Section values promoted from published characteristics and maximum ratings.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

199X Svetlana

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Voltage 7.5 ±

    0.37 V

    SourcePage1-2

  • Current @

    7.5 V

    SourcePage1-2

  • Input

    53 pF

    SourcePage1-2

  • Output

    1.5 pF

    SourcePage1-2

  • Feedback

    34 pF

    SourcePage1-2

Other

  • Maximum-signal DC plate current

    4 A

    SourcePage1-2

  • Plate Dissipation

    10000 W

    SourcePage1-2

  • Grid Dissipation

    250 W

    SourcePage1-2

  • DC plate voltage 7000

    9000 V

    TypicalOperation

  • Plate current 4.0

    4 A

    TypicalOperation

  • DC grid voltage -620

    -930 V

    TypicalOperation

  • DC grid current* 0.275

    430 mA

    TypicalOperation

  • Peak cathode RF voltage* 370

    390 V

    TypicalOperation

  • Driving power* 260

    570 W

    TypicalOperation

  • Plate Power output 19

    29000 W

    TypicalOperation