Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Beam Power
Other
Heater voltage
6.3 V
Heater current
450 mA
Maximum plate voltage
250 V
Maximum screen voltage
250 V
Maximum plate dissipation
12 W
Maximum screen dissipation
2 W
Triode-connected dissipation
14 W
TriodeConnection
Application
Primary application
Beam output tetrode equivalent to 6AQ5 for audio power service.