Data set 01
1937 Osram Valves
Published operating points and test conditions from this source.
Pentode
Other
Optimum load resistance
7800 ohm
Published operating data
Power - Pentode (NOT beam) ·Pentode
High-transconductance Osram audio power pentode with 10 W plate dissipation.
OSRAM N43 pentode for amplification or power-output service as specified in the supplied datasheet.
Medium 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from the approved datasheet.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Optimum load resistance
7800 ohm
Published operating data
Data set 02
Published operating points and test conditions from this source.
Heater/Filament Voltage
4 V
Published datasheet value
Heater/Filament Current
2 A
Published datasheet value
Maximum Anode Voltage
250 V
Published datasheet value
Maximum Screen Voltage
250 V
Published datasheet value
Maximum Anode Dissipation
10 W
Published datasheet value
Mutual Conductance
10000 µS
Published datasheet value