Data set 01
1972 Thomson CSF
Published operating points and test conditions from this source.
Magnetron
Characteristic
Frequency
9375 MHz
Frequency Tolerance
30 MHz
Pulse Voltage
20 to 23 kV
Peak Output Power Minimum
225 kW
Other
Heater Surge Current Maximum
15 A
Warm-up Time Minimum
180 s
Pulse Duration
0.2 to 6 us
Duty Cycle Maximum
0.001
Rate of Rise of Voltage
60 to 160 kV/us
Repetition Rate
160 to 5000 Hz
Peak Input Power Maximum
630 kW
Average Input Power Maximum
630 W
Peak Anode Voltage Maximum
23 kV
Peak Anode Current Maximum
27.5 A
Typical RF Peak Output
235 kW