Skip to main content

Specialized - Thyratron ·Thyratron

M8204

Special-quality xenon tetrode thyratron with negative-control characteristic, designed for equipment exposed to mechanical vibration and shock where statistically controlled electrical characteristics are required.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B7G
Base pins
7
Nominal heater
6.3 V / -

Description

SPECIAL QUALITY TETRODE THYRATRON 100mA special quality tetrode xenon thyratron with negative control characteristic for use in equipment where mechanical vibration and shocks are unavoidable and where statistically controlled major electrical characteristics are required. PRELIMINARY DATA This data should be read in conjunction with the The supplied datasheet publishes electrical ratings and characteristics for this thyratron device.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B7G
Base pins
7
Nominal heater voltage
6.3 V
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
650 V
Max cathode current
100 mA

Gas-discharge device.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Heater or filament voltage

    6.3 V

  • MaxPlateVoltage

    650

    Promoted field source value

  • MaxCathodeCurrent

    0.1

    Promoted field source value

Data set 02

1971 Mullard Gas Filled Tubes

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Heater/filament voltage

    6.3 V