Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Magnetron
Other
Frequency Minimum
9345 MHz
Frequency Maximum
9405 MHz
Tuning Pulling Range
14 MHz
Rate of Rise of Voltage Maximum
60 kV/us
Duty Cycle Maximum
0.001
Magnetic Field
4800 Oe
Efficiency Minimum
25 percent
Typical Peak Anode Voltage
55 kV
Typical Peak Anode Current
5 A
Typical Pulse Duration
1 us
Typical PRF
1000 pps
Typical Peak Output Power
8 kW