Data set 01
1967 Mullard Receiving and Amplifying Valves
Published operating points and test conditions from this source.
Pentode
Other
Ci n
10 pF
Published in approved EF184 target datasheet entry; Section1
Co ut
3 pF
Published in approved EF184 target datasheet entry; Section1
Cg l - g 2
2.8 pF
Published in approved EF184 target datasheet entry; Section1
P g2 max
900 mW
Published in approved EF184 target datasheet entry; Section1
T b u l b max
180 °C
Published in approved EF184 target datasheet entry; Section1
gm =2
2 mA
Published in approved EF184 target datasheet entry; Section1