Data set 01
1971 NEC
Published operating points and test conditions from this source.
TravelingWave
Other
frequency range [1]
7.2
frequency range 7.2 kMc to 8.5 kMc. The nominal gain is 40db at 1
frequency range [2]
8.5
frequency range 7.2 kMc to 8.5 kMc. The nominal gain is 40db at 1
frequency range [3]
40
frequency range 7.2 kMc to 8.5 kMc. The nominal gain is 40db at 1
frequency range [4]
1
frequency range 7.2 kMc to 8.5 kMc. The nominal gain is 40db at 1
watt output level with a typical saturation output power of
10 W
watt output level with a typical saturation output power of 10 watts,
permanent magnet focusing mount, type LD
550
permanent magnet focusing mount, type LD-550B Mount, incorporated with
Published value
1
1. PPM Focused and Field Replaceable.
Published value
2
2. Depressed Collector Operation for Improved Efficiency.
Collector Voltage (Eb) [1]
1600 V
Collector Voltage (Eb) 1600 Vde 3000 Vdc
Collector Voltage (Eb) [2]
3000 V
Collector Voltage (Eb) 1600 Vde 3000 Vdc
Collector Current (Ib) . ooooo e
34 A
Collector Current (Ib) . ooooo e 34 mA dc
Helix Voltage (Bw) [1]
2700 V
Helix Voltage (Bw) . 2700 Vdc 34,00 Vdc
Helix Voltage (Bw) [2]
3400 V
Helix Voltage (Bw) . 2700 Vdc 34,00 Vdc
Accelerating Anode Voltage
3400 V
Accelerating Anode Voltage 3400 Vdc
Accelerating Anode Current
1 A
Accelerating Anode Current 1.0 mA dc
Focusing flectrode Voltage ~
-20 V
Focusing flectrode Voltage ~-20 Vdc
Collector Dissipation
56 W
Collector Dissipation 56 W
Collector Seal Temperature
130
Collector Seal Temperature 130 °C -
Mount Ambient Temperature Range [1]
-10
Mount Ambient Temperature Range -10 °cC +55 °C
Mount Ambient Temperature Range [2]
55
Mount Ambient Temperature Range -10 °cC +55 °C
Cathode Heating Time
90
Cathode Heating Time 90 sec,
Cold input and output match over [1]
7.2
Cold input and output match over 7.2 to 7.65, 7.65 to &.1 and 8.1 to
Cold input and output match over [2]
7.65
Cold input and output match over 7.2 to 7.65, 7.65 to &.1 and 8.1 to
Cold input and output match over [3]
7.65
Cold input and output match over 7.2 to 7.65, 7.65 to &.1 and 8.1 to
Cold input and output match over [4]
1
Cold input and output match over 7.2 to 7.65, 7.65 to &.1 and 8.1 to
Cold input and output match over [5]
8.1
Cold input and output match over 7.2 to 7.65, 7.65 to &.1 and 8.1 to
Heater Current at [1]
6.3 A
Heater Current at 6.3 Volts .. ..... . cereses 0.6 A
Heater Current at [2]
600 mA
Heater Current at 6.3 Volts .. ..... . cereses 0.6 A
Frequency [1]
7.8
Frequency 7.8 kMc 8.5 kMc
Frequency [2]
8.5
Frequency 7.8 kMc 8.5 kMc
RF Output Power [1]
8.5 W
RF Output Power : 8.5W 7.5 W L.5W
RF Output Power [2]
7.5 W
RF Output Power : 8.5W 7.5 W L.5W
RF Output Power [3]
5 W
RF Output Power : 8.5W 7.5 W L.5W
(
0.5
(0.5 mW input level)
RF Saturated Output Power [1]
14 W
RF Saturated Output Power 14,.0 W 12,0 W 10.0 W
RF Saturated Output Power [2]
120 W
RF Saturated Output Power 14,.0 W 12,0 W 10.0 W
RF Saturated Output Power [3]
10 W
RF Saturated Output Power 14,.0 W 12,0 W 10.0 W
Small Signal Gain Li, db
43
Small Signal Gain Li, db 43 db L0 db
(
0.1
(0.1 mW input level)
helix current due to other magnetic materials less than
100 mA
helix current due to other magnetic materials less than 0.1 mA.
Published value
5 V
5. Applications of Voltage
Published value
5.1 V
5.1 Apply the heater voltage and allow a minimum warm-up period
Published value
5.2 V
5.2 Set the focusing electrode, collector and helix voltages
Published value
5.3 V
5.3 Switch on all voltages. Accelerating anode voltage should be
Published value
5.4 A
5.4, Adjust tube position carefully to optimize current transmission
Published value
5.5
5.5 Apply the specified rf drive and adjust accelerating anode
Published value
5.6 V
5.6 Adjust the helix voltage for optimum operation. The helix
voltage should never be made to exceed
3400 V
voltage should never be made to exceed 3400 voltis or fall
below
2700 V
below 2700 volts. If the helix voltage is above or below
The collector voltage should never be depressed below
1600 V
The collector voltage should never be depressed below 1600 volts
Published value
5.7 V
5.7 Readjust tube position and adjust the focusing electrode voltage