Data set 01
1937 Osram Valves
Published operating points and test conditions from this source.
Triode
Other
Optimum load resistance
20000 ohm
Published operating data
Voltage - Triode (single) ·Triode
OSRAM triode for receiving-equipment amplification, detection, or power-output service as specified in its manufacturer datasheet.
OSRAM L30 triode for amplification, detection, or power-output service as specified in the supplied datasheet.
European 4-pin base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from the approved datasheet. Osram L30 low-impedance indirectly heated receiving triode for low-frequency amplifier service and AC/DC series or parallel heater operation. Nominal heater 13 V at 0.3 A, seven-pin base. Maximum anode voltage 200 V. Manufacturer characteristic constants at its specified test point: amplification factor 12, plate resistance about 2860 Ω, gm 4.2 mA/V. The 250 V listing belongs to the adjacent H30, not L30; manufacturer suggests an approximately 6000 Ω optimum load.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Optimum load resistance
20000 ohm
Published operating data