Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Rectifier
Other
KY2
1
KY21A's in a conventional single phase full wave circuit will supply a d-c power
output of [1]
5 V
output of 5 kilowatts (3500 volts at 1.5 amperes) with a choke input filter.
output of [2]
3500 V
output of 5 kilowatts (3500 volts at 1.5 amperes) with a choke input filter.
output of [3]
1.5 V
output of 5 kilowatts (3500 volts at 1.5 amperes) with a choke input filter.
Voltage
2.5 V
Voltage - - - - - - - - - 2.5 volts
Current
10 A
Current - - - - - - - - 10 amperes
Filament Heating Time (minimum)
30 s
Filament Heating Time (minimum) - - - - - 30 seconds
Peak Inverse Anode Voltage
11000 V
Peak Inverse Anode Voltage - - - - - 11,000 max. volts
Peak Anode Current
3 A
Peak Anode Current - - - - - - - 3 max. amperes
Average Anode Current
75 A
Average Anode Current - - - - - - .75 max. amperes
Supply Frequency
150
Supply Frequency - - - - - - - - - - - - 150 max. C.P.S.
Temperature Limits, Condensed Mercury [1]
20
Temperature Limits, Condensed Mercury - - - - - - - 20° to 60° Centigrade
Temperature Limits, Condensed Mercury [2]
60
Temperature Limits, Condensed Mercury - - - - - - - 20° to 60° Centigrade
should be held at the rated value of
2.5 V
should be held at the rated value of 2.5 volts. Variations in filament voltage must be kept within the range
of [1]
2.4 V
of 2.4 to 2.6 volts. The filament of the KY2IA should be allowed to reach operating temperature before
of [2]
2.6 V
of 2.4 to 2.6 volts. The filament of the KY2IA should be allowed to reach operating temperature before
the plate voltage is applied. Under normal conditions, a delay of approximately
30 s
the plate voltage is applied. Under normal conditions, a delay of approximately 30 seconds will be re-
When a KY2
1
When a KY21A is first installed, the filament should be operated at rated voltage for approximately
The ratio of d-c plate voltage to control voltage varies from about [1]
87 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
The ratio of d-c plate voltage to control voltage varies from about [2]
1 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
The ratio of d-c plate voltage to control voltage varies from about [3]
1000 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
The ratio of d-c plate voltage to control voltage varies from about [4]
130 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
The ratio of d-c plate voltage to control voltage varies from about [5]
1 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
The ratio of d-c plate voltage to control voltage varies from about [6]
3500 V
The ratio of d-c plate voltage to control voltage varies from about 87:1 at 1000 volts to 130:1 at 3500 volts.
supply [1]
100 V
supply 100 to 150 volts of bias from a small pack. This grid voltage is satisfactory for all normal plate
supply [2]
150 V
supply 100 to 150 volts of bias from a small pack. This grid voltage is satisfactory for all normal plate
voltages. It will usually be advisable to protect the grid of the KY2
1
voltages. It will usually be advisable to protect the grid of the KY21A by means of a current limiting