Data set 01
1962 ITT
Published operating points and test conditions from this source.
Rectifier
Characteristic
Heater Voltage
5 V
Heater Current
15-27 A
Anode Voltage Drop
70 V
Minimum Heating Time
300 s
Other
Maximum Peak Inverse Anode Voltage
30000 V
Maximum Peak Anode Current
500 A
Maximum Average Anode Current
2 A
Maximum RMS Anode Current
15 A
Environmental
Ambient Temperature Range
-55 to +125 C