Skip to main content

Voltage - Triode (with diode, heptode or hexode) ·Diode-Diode-Triode

KBC32

Low-consumption battery double-diode triode for detection and audio-frequency voltage amplification. The paired diodes provide receiver rectification while the triode amplifies the recovered signal from an economical directly heated filament.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
3
Base
-
Socket code
IO
Base pins
-
Nominal heater
2 V / 50 mA

Description

Battery double-diode triode with directly heated filament for detector and voltage-amplifier service.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
IO
Base pins
-
Nominal heater voltage
2 V
Nominal heater current
50 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

3 physical sections, each with unique specifications.

Section 1

Diode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Representative of two diode detector sections.

Section 2

Diode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Second physical detector diode section added in approved reconciliation.

Section 3

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
21000 Ω
Transconductance
0.0012 S
Amplification factor
25

AF amplifier triode section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1951 Mullard Valve and Service Manual

Published operating points and test conditions from this source.

SECTION 1

Diode

Characteristic

  • HeaterOrFilamentVoltage

    2 V

  • HeaterOrFilamentCurrent

    50 mA

Data set 02

1958 Mullard Receiving Tubes

Published operating points and test conditions from this source.

SECTION 3

Triode

Characteristics

  • Plate Voltage

    100 V

  • Plate Current

    2.4 mA

  • Amplification Factor

    25 ratio