Skip to main content

Specialized - Magnetron ·Magnetron

JP97A

Forced-air-cooled packaged fixed-frequency X-band pulsed magnetron, equivalent to 2J42 except for operating frequency.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Forced-air-cooled packaged pulsed magnetron for fixed-frequency X-band service; equivalent to 2J42 except frequency. Published ratings, characteristics, operating data, capacitances, microwave/noise data, or gauge-head data were retained according to the physical device and mapped only to compatible locked-schema fields.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Magnetron

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Pulsed magnetron; source refers electrical data to 2J42 except for operating frequency.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Magnetron

Characteristics

  • Frequency range

    9210 to 9270 MHz

  • Minimum peak output power

    7 kW

Other

  • Electrical data reference

    2J42

    EquivalentExceptFrequency