Data set 01
196X Nixie Russian 2
Published operating points and test conditions from this source.
Nixie
Other
DC operating current
2.5 to 3.5 mA
DC supply
Pulsating operating current average
0.8 to 1.6 mA
50 Hz pulsating supply
Supply voltage
200 to - V
Minimum stated source/supply voltage
Ignition voltage
- to 170 V
Published datasheet value
Maintaining voltage / anode-cathode drop
- to 150 V
Published datasheet value
Indication current
- to 2.5 mA
Published datasheet value
Characteristic
Brightness
50 to - cd/m^2
Minimum
Viewing angle
60 to - deg
Minimum
Service life
5000 to - h
Minimum